Datasets:
Modalities:
Tabular
Size:
10M - 100M
| # 3W Dataset's main configuration file. | |
| # | |
| # All settings inherent in the 3W Dataset that can be used by your | |
| # consumers, including the 3W Toolkit, are maintained in this file. | |
| # In this file, we use the configuration language supported by the | |
| # configparser module. | |
| # Versions in gereral | |
| # | |
| [VERSION] | |
| # 3W Dataset version (may be different than 3W Toolkit version) | |
| DATASET = 2.0.0 | |
| # Parquet files properties in general | |
| # | |
| [PARQUET_FILE_PROPERTIES] | |
| timestamp = Instant at which observation was generated | |
| ABER-CKGL = Opening of the GLCK (gas lift choke) [%%] | |
| ABER-CKP = Opening of the PCK (production choke) [%%] | |
| ESTADO-DHSV = State of the DHSV (downhole safety valve) [0, 0.5, or 1] | |
| ESTADO-M1 = State of the PMV (production master valve) [0, 0.5, or 1] | |
| ESTADO-M2 = State of the AMV (annulus master valve) [0, 0.5, or 1] | |
| ESTADO-PXO = State of the PXO (pig-crossover) valve [0, 0.5, or 1] | |
| ESTADO-SDV-GL = State of the gas lift SDV (shutdown valve) [0, 0.5, or 1] | |
| ESTADO-SDV-P = State of the production SDV (shutdown valve) [0, 0.5, or 1] | |
| ESTADO-W1 = State of the PWV (production wing valve) [0, 0.5, or 1] | |
| ESTADO-W2 = State of the AWV (annulus wing valve) [0, 0.5, or 1] | |
| ESTADO-XO = State of the XO (crossover) valve [0, 0.5, or 1] | |
| P-ANULAR = Pressure in the well annulus [Pa] | |
| P-JUS-BS = Downstream pressure of the SP (service pump) [Pa] | |
| P-JUS-CKGL = Downstream pressure of the GLCK (gas lift choke) [Pa] | |
| P-JUS-CKP = Downstream pressure of the PCK (production choke) [Pa] | |
| P-MON-CKGL = Upstream pressure of the GLCK (gas lift choke) [Pa] | |
| P-MON-CKP = Upstream pressure of the PCK (production choke) [Pa] | |
| P-MON-SDV-P = Upstream pressure of the production SDV (shutdown valve) [Pa] | |
| P-PDG = Pressure at the PDG (permanent downhole gauge) [Pa] | |
| PT-P = Downstream pressure of the PWV (production wing valve) in the production tube [Pa] | |
| P-TPT = Pressure at the TPT (temperature and pressure transducer) [Pa] | |
| QBS = Flow rate at the SP (service pump) [m3/s] | |
| QGL = Gas lift flow rate [m3/s] | |
| T-JUS-CKP = Downstream temperature of the PCK (production choke) [oC] | |
| T-MON-CKP = Upstream temperature of the PCK (production choke) [oC] | |
| T-PDG = Temperature at the PDG (permanent downhole gauge) [oC] | |
| T-TPT = Temperature at the TPT (temperature and pressure transducer) [oC] | |
| class = Label of the observation | |
| state = Well operational status | |
| # Common properties of all event types covered by the 3W Project | |
| # | |
| [EVENTS] | |
| # Internal names of all event types | |
| NAMES = NORMAL, ABRUPT_INCREASE_OF_BSW, SPURIOUS_CLOSURE_OF_DHSV, | |
| SEVERE_SLUGGING, FLOW_INSTABILITY, RAPID_PRODUCTIVITY_LOSS, | |
| QUICK_RESTRICTION_IN_PCK, SCALING_IN_PCK, | |
| HYDRATE_IN_PRODUCTION_LINE, HYDRATE_IN_SERVICE_LINE | |
| # Simulated and hand-drawn instances | |
| EXTRA_INSTANCES_TRAINING = -1 | |
| # Offset between an undesirable event's label and its transient label | |
| TRANSIENT_OFFSET = 100 | |
| # This section defines default properties for a specific event type | |
| # | |
| [NORMAL] | |
| LABEL = 0 | |
| DESCRIPTION = Normal Operation | |
| # This section defines default properties for a specific event type | |
| # | |
| [ABRUPT_INCREASE_OF_BSW] | |
| LABEL = 1 | |
| DESCRIPTION = Abrupt Increase of BSW | |
| TRANSIENT = True | |
| # This section defines default properties for a specific event type | |
| # | |
| [SPURIOUS_CLOSURE_OF_DHSV] | |
| LABEL = 2 | |
| DESCRIPTION = Spurious Closure of DHSV | |
| TRANSIENT = True | |
| WINDOW = 180 | |
| STEP = 15 | |
| # This section defines default properties for a specific event type | |
| # | |
| [SEVERE_SLUGGING] | |
| LABEL = 3 | |
| DESCRIPTION = Severe Slugging | |
| TRANSIENT = False | |
| # This section defines default properties for a specific event type | |
| # | |
| [FLOW_INSTABILITY] | |
| LABEL = 4 | |
| DESCRIPTION = Flow Instability | |
| TRANSIENT = False | |
| # This section defines default properties for a specific event type | |
| # | |
| [RAPID_PRODUCTIVITY_LOSS] | |
| LABEL = 5 | |
| DESCRIPTION = Rapid Productivity Loss | |
| TRANSIENT = True | |
| # This section defines default properties for a specific event type | |
| # | |
| [QUICK_RESTRICTION_IN_PCK] | |
| LABEL = 6 | |
| DESCRIPTION = Quick Restriction in PCK | |
| TRANSIENT = True | |
| # This section defines default properties for a specific event type | |
| # | |
| [SCALING_IN_PCK] | |
| LABEL = 7 | |
| DESCRIPTION = Scaling in PCK | |
| TRANSIENT = True | |
| # This section defines default properties for a specific event type | |
| # | |
| [HYDRATE_IN_PRODUCTION_LINE] | |
| LABEL = 8 | |
| DESCRIPTION = Hydrate in Production Line | |
| TRANSIENT = True | |
| # This section defines default properties for a specific event type | |
| # | |
| [HYDRATE_IN_SERVICE_LINE] | |
| LABEL = 9 | |
| DESCRIPTION = Hydrate in Service Line | |
| TRANSIENT = True | |
| # Settings related to the Parquet format | |
| # | |
| [PARQUET_SETTINGS] | |
| # Used/chosen extension | |
| PARQUET_EXTENSION = .parquet | |
| # Used/chosen extension engine | |
| PARQUET_ENGINE = pyarrow | |
| # Used/chosen extension compression | |
| PARQUET_COMPRESSION = brotli |